63
Installing the Avaya G600 Media Gateway
October 2002
Correct Shipping Errors
1 Red-tag all defective and over-shipped equipment and return according to the nearest
Material Stocking Location (MSL) instructions.
2 Direct all short-shipped reports to the nearest MSL. Contact the appropriate location for
specific instructions. For streamlined implementation, call 1-800-772-5409.
Set the Carrier Address ID
Set the Carrier Address ID either before or after installing each media gateway.
1 Loosen the thumb screws on the fan assembly and pull it straight out as shown in ‘‘Fan
assembly removal’’ on page 64. Leave the fan assembly off until the unit is completely
installed in the rack.
2 Verify and, if necessary, set the carrier address ID for each media gateway as shown in
‘‘Setting media gateway carrier address ID’’ on page 64
. "A" settings are for the media
gateway in the A location, "B" settings are for the media gateway in the B location, "C"
settings are for the media gateway in the C location, and "D" settings are for the media
gateway in the D location. "E" settings are not used in this configuration.
104410147 3B1E-W Wide Gap Gas Tube X
105514756 3C1S Analog Line Protector - Solid State X
102904893 4B1C Carbon Block with Heat Coil X
104401856 4B1E-W Wide Gap Gas Tube w/Heat Coil X
104386545 4C1S Analog Line Protector - Solid State with Heat Coil X
105581086 4C3S-75 Digital Voice Circuit Protector - Solid State X
406144907 ITW LINX Gas Tube, Avalanche Suppress X
901007120 ITW Linx Ground Bar (used with above) X
406304816 ITW Linx Replacement Fuse X
103972758 Data Link Protector (1 circuit) X
103972733 Data Link Protector (8 circuits) X
407063478 Electrostatic Discharge (ESD) Wrist Strap
Comcodes for equipment used with Avaya G600 — Continued
Comcode Description Optional