203
Testing the Complete Configuration
October 2002
Testing Port Network Equipment
These tests verify that the Time Division Multiplexing (TDM) cables, terminators, and the
Inter-Cabinet Cables (MCC1 Media Gateway) work. If a FAIL Result code is seen, check these
cables. If problems persist, refer to the maintenance book for your configuration
.
Check Port Network Status for Each Media
Gateway
The port network status may suggest problem areas. Tests described later provide more specific
diagnostic information.
1 Type status port-network number <1-64> and press Enter.
Verify the screen displays a Port Network Status screen similar to the one in "Sample
Port Network Status Screen for Cabinet 1—S8700 Multi-Connect".
Verify these service states:
Sample Port Network Status Screen for Cabinet 1—S8700 Multi-Connect
Field Service State
TDM Bus A in
TDM Bus B in
Tone/Clock in
PKT in
status port-network 1
PORT NETWORK STATUS
Major Minor Warning Carrier PN Control FIBER-
PN Alarms Alarms Alarms Locs Active Standby LINK Endpoints Mode
1 1 0 195 01A up up 1 B-PNC 01B02-03E04 standby
01B 1 A-PNC 01A01-01E04 active
TDM Service Control Dedicated TONE/ Service System System
Bus State Channel Tones CLOCK State Clock Tones
A in y n 01B in standby standby
B in n y 01A in active active
Service Major Minor Bus Open Bus
PKT State Alarms Alarms Faults Leads
1 in n n 0 0
Command: