Installing and Wiring Telephones
October 2002
Install External Ringing
Connections for external ringing are at an information outlet. The media gateway side of the
Main Distribution Frame (MDF) is connected to a TN2183 (or equivalent) Analog Line circuit
pack. The circuitry and power source for the device are provided by the customer.
NOTE:
A maximum of 3 devices can connect to 1 analog line circuit pack port.
1 Wire the ringing device to the information outlet as shown in ‘‘3-Pair and 4-Pair
Modularity’’ on page 172 and ‘‘Example Adjunct Power Connections’’ on page 150.
2 Administer per the Administrator’s Guide for Avaya MultiVantage Software.
3-Pair and 4-Pair Modularity
Figure notes
1 Port Circuit Pack
2 Media Gateway Connector
Pins
(3-Pair Modularity)
3 Main Distribution Frame
(MDF) Pins (3-Pair
Modularity)
4 Input to Information Outlet
(4-Pair Modularity)
5 Adjunct Power
6 Output From Information Outlet
(4-Pair Modularity)
7 Voice or Data Terminal Pins