212
Testing the Complete Configuration
October 2002
Test Terminating Trunk Transmission
The Terminating Trunk Transmission Test provides for extension number access to 3 tone
sequences that can be used for trunk transmission testing from the distant end of the trunks.
1 Type change system-parameters maintenance and press Enter and go to screen 2.
2 Under TERMINATING TRUNK TRANSMISSION TEST ( Extension ), type in 3
extension numbers in the 3 fields provided:
Test Type 100:_______Test Type 102:_______Test Type 105:_______
Test the C-LAN Connectivity
1 To test the external IP connections, ping the C-LAN circuit pack and ping a known
computer connected to your network. If everything is configured correctly, the Result
column on the Ping Results screen reads PASS. If it reads ABORT, verify the IP-address
information and check the connectivity, including the cabling.
2 To ping the C-LAN server, type ping ip-address IPaddress board UUCSS and press
Enter.
The variable IPaddress is the IP address of the TN799DP C-LAN circuit pack and
UUCSS is the cabinet, carrier, and slot of the TN799DP C-LAN circuit pack.
3 Type ping ip-address IPaddress board UUCSS and press Enter.
The variable IPaddress is the IP address of another computer beyond the gateway and
UUCSS is the cabinet, carrier, and slot of the TN799DP C-LAN circuit pack.
Test Type Test Features
Test type 100 5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
Test Type
102
9 seconds of 1004 Hz tone at 0 dB
1 second of silence
Cycle is repeated until disconnect, which is forced after 24
hours
Test Type
105
9 seconds of 1004 Hz tone at -16 dB
1 second of silence
9 seconds of 404 Hz tone at -16 dB
1 second of silence
9 seconds of 2804 Hz tone at -16 dB
30 seconds of silence
0.5 seconds of test progress tone (2225 Hz)
About 5 seconds of silence
Forced disconnect