205
Testing the Complete Configuration
October 2002
4 Click on Interchange again to interchange the active and standby servers back to the
original status.
Test the IPSI Circuit Pack
Use Avaya Site Administration.
1 Type test ipserver-interface UUC and press Enter to test all clock and packet interface
components within the IPSI circuit pack.
2 Verify the screen displays Test Results screen similar to "Sample IPSI 01A Test Results
Screen — Page 1, S8700 Multi-Connect".
Sample IPSI 01A Test Results Screen — Page 1, S8700 Multi-Connect
Test License File
!
CAUTION:
Wait at least 30 minutes after you install the license before you do the test.
Check the LIC-ERR maintenance object.
1 Type test license [ short | long ] and press Enter.
2 Verify the screen displays a Test Results screen similar to ‘‘Sample Test Results screen
for test license’’ on page 206
test ipserver-interface 1a Page 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A TONE-BD 46 PASS
01A TONE-BD 52 PASS
01A0201 ETR-PT 42 PASS
01A0201 ETR-PT 43 PASS
01A0202 ETR-PT 42 PASS
01A0202 ETR-PT 43 PASS
01A0203 ETR-PT 42 PASS
01A0203 ETR-PT 43 PASS
01A0204 ETR-PT 42 PASS
01A0204 ETR-PT 43 PASS
01A0205 ETR-PT 42 PASS
01A0205 ETR-PT 43 PASS
01A0206 ETR-PT 42 PASS
01A0206 ETR-PT 43 PASS
01A0207 ETR-PT 42 PASS
press CANCEL to quit -- press NEXT PAGE to continue