132
Connecting to the Customer’s Network
October 2002
2 Set the Type field to ethernet.
3 Set the Port field to correspond to the circuit pack location.
The port number (final two digits) is always 33 for the TN2501AP circuit pack.
4 Set the Link field to an unassigned or next-available link number.
5 Set the Network uses 1’s for Broadcast Address? field according to the
your network requirements.
6 Type a unique name in the Name field.
7 Press Enter to save your changes.
Administer IP routing (if used)
1 Type add ip-route and press Enter.
2 Administer IP routes to the TN2501AP circuit pack.
3 Press Enter to effect the changes.
Test the IP connections
1 Click Start > Run to open the Run dialog box.
2 Type command and press Enter to open an MS-DOS command window.
3 Type ping ipaddress, where ipaddress is a known computer on the network and press
Enter to verify connectivity.
4 Using Avaya Site Administration, type status link to test the new IP connections that
you have administered.
add data-module 30006 Page 1 of 1
DATA MODULE
Data Extension: 30006 Name: VAL#2 Data Module
Type: ethernet
Port: 1b0333
Link: 5
Network uses 1’s for Broadcast Addresses? y