131
Connecting to the Customer’s Network
October 2002
2 Set the Enable Eth Pt field to y.
3 Set the Type field to VAL.
4 Type the circuit pack location in the Slot field (UUCSS).
If a TN2501AP circuit pack is not at this location when you submit the screen, the
software prompts you to enter a VAL circuit pack location.
5 In the Node Name field, enter the Node Name you entered with the change node-names
ip command.
If you press Help, a list of administered node names appears (including the name you
administered with the change node-names ip command), and you can select from the list.
6 Set the Subnet Mask field according to your network requirements.
Gateway address is usually the same as the TN2501AP circuit pack’s IP address, usually
with the fourth octet changed. Be sure to set this address according to your network
requirements.
7 Press Enter to save the changes.
Administer the data module
1 Type add data-module extension and press Enter.
The Data Module screen appears. Use this screen to administer the data module that is
associated with the TN2501AP ethernet port.
change ip-interfaces Page 1 of 6
IP INTERFACES
Enable Net
Eth Pt Type Slot Code Sfx Node Name Subnet Mask Gateway Address Rgn
y C-LAN 01C16 TN799 C st12clan 255.255.0 .0 172.22 .22 .254 1
y MEDPRO 01E04 TN2302 st12prowler#1 255.255.0 .0 172.22 .22 .254 1
y VAL 01C08 TN2501 VAL#1 255.255.0 .0 172.22 .22 .254
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .