117
Connecting to the Customer’s Network
October 2002
1 Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press Enter. The variable
nnn.nnn.nnn.nnn is the IP address of the TN799DP and UUCSS is the cabinet, carrier,
and slot of the TN799DP C-LAN circuit pack.
2 Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press Enter. The variable
nnn.nnn.nnn.nnn is the IP address of the customer’s gateway and UUCSS is the cabinet,
carrier, and slot of the TN799DP C-LAN circuit pack.
3 Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press Enter. The variable
nnn.nnn.nnn.nnn is the IP address of another computer beyond the gateway and UUCSS
is the cabinet, carrier, and slot of the TN799DP C-LAN circuit pack.
The TN799DP C-LAN circuit pack is now installed in the media gateway and connected to the
IP network.
ping ip-address 192.168.10.21
PING RESULTS
End-pt IP Port Port Type Result Time(ms) Error Code
192.168.10.21 01A13 MEDPRO PASS 10 1124