122
Connecting to the Customer’s Network
October 2002
5 Type display circuit-pack and press Enter. Verify that the TN2302AP shows up in the
Code column.
6 Type change ip-interfaces and press Enter.
.Type in the fo llowing info rmation for the TN2302AP IP Media Processo r and TN799D P C-LAN:
NOTE:
Enable the Ethernet port last, after you have filled in the information in the other fields.
• Set Slot field to UUCSS, where UUCSS is the cabinet, carrier, and slot.
• The Code and SFX fields are automatically populated with TN2302AP circuit
packs.
change node-names ip Page 1 of 1
IP NODE NAMES
Name IP Address Name IP Address
cognac 172.16 .19 .2 . . .
default 0 .0 .0 .0 . . .
medpro 192.168.1 .82 . . .
prowler 192.168.1 .83 . . .
prowler1 172.16 .19 .221 . . .
prowler2 172.16 .19 .222 . . .
prowler3 172.16 .19 .223 . . .
prowler4 172.16 .19 .224 . . .
prowler5 172.16 .19 .225 . . .
sr1clan1 192.168.1 .80 . . .
sr1clan2 172.16 .19 .220 . . .
traf-clan 172.16 .19 .118 . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
( 12 of 12 administered node-names were displayed )
Use ’list node-names’ command to see all the administered node-names
change ip-interfaces Page 1 of 15
IP INTERFACES
Enable Net
Eth Pt Type Slot Code Sfx Node Name Subnet Mask Gateway Address Rgn
n MEDPRO 01B11 TN2302 prowler 255.255.255.0 172.16 .23 .254 1
y C-LAN 05B11 TN799 C sr1clan2 255.255.248.0 172.16 .23 .254 3
y MEDPRO 07B09 TN2302 prowler1 255.255.248.0 172.16 .23 .254 3
y MEDPRO 07B10 TN2302 prowler2 255.255.248.0 172.16 .23 .254 3
y MEDPRO 03A11 TN2302 prowler3 255.255.248.0 172.16 .23 .254 2
y MEDPRO 05A12 TN2302 prowler5 255.255.248.0 172.16 .23 .254 2
y C-LAN 01A11 TN799 C traf-clan 255.255.248.0 172.16 .23 .254 2
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .
n 255.255.255.0 . . .