The azimuth counter-clockwise limit switch cannot be read. The azimuth
RIOM reports this error. This does not indicate the counter-clockwise limit
switch is broken, it indicates the digital input cannot be read by the RIOM.
The azimuth motor had entered an error state. The azimuth RIOM reports
this error. This indicates the azimuth motor can no longer move due to a
physical problem.
The elevation motor had entered an error state The elevation RIOM reports
this error. This indicates the elevation motor can no longer move due to a
physical problem.
The polarization motor had entered an error state The Polarization RIOM
reports this error. This indicates the polarization motor can no longer
move due to a physical problem.
The navigation RIOM cannot be communicated with.
The wing motor had entered an error state. The wing RIOM reports this
error. This indicates the wing motor can no longer move due to a physical
problem.
The wing left deploy switch cannot be read. The wing RIOM reports this
error. This does not indicate the left deploy switch is broken; it indicates
the digital input cannot be read by the RIOM.
The wing right deploy switch cannot be read. The wing RIOM reports this
error. This does not indicate the right deploy switch is broken; it indicates
the digital input cannot be read by the RIOM.
The wing left stow switch cannot be read. The wing RIOM reports this
error. This does not indicate the left stow switch is broken; it indicates the
digital input cannot be read by the RIOM.
The wing right stow switch cannot be read. The wing RIOM reports this
error. This does not indicate the right stow switch is broken; it indicates
the digital input cannot be read by the RIOM.
The wing elevation safety switch cannot be read. The wing RIOM reports
this error. This does not indicate the elevation safety switch is broken, it
indicates the digital input cannot be read by the RIOM.
The RIOM configured as the Digital Input 0 through 4 register cannot be
communicated with.
The elevation inclinometer cannot be read or the inclinometer device is not
functioning.
The pitch and roll (tilt) inclinometer cannot be read or the inclinometer
device is not functioning.
The feed bit digital inputs cannot be read.
The Green and Red digital inputs cannot be read.
The Legacy 1RU Rack Controller cannot be communicated to.
The RIOM configured as the Digital Output 0 register cannot be
communicated with. AAQ 1500 hardware is configured to use Digital
Output 0 as the LNB control.
The RIOM configured as the Digital Output 1 through 3 register cannot be
communicated with.
The controller has not received a valid GPS location.