AvL Proprietary and Confidential
Content is Subject to Change without Notice Page 26 of 195
3.4 AAQ Remote Network Settings Tool
The AAQ Remote Settings tool is utilized to customize the AAQ Network IP settings using login
level 4 or above.
Main Window → File → Settings
AAQ Network Interface Options
Modems, beacon receivers, etc. will sometimes require the AAQ controller to be configured on
the device network, enabling communications between the two devices.
Figure 3.4 - Advanced Network Settings Tool
When the ACU is set to use DHCP, make sure that the server is also
a DNS server. Using a DHCP server without a DNS server will cause
the ACU to receive a valid IP address that is unknown to the user.
Customer IPs may be changed in accordance with customer device
requirements. Once a new address is entered, click “Apply” to
make the change.
The service IP is permanent and available for recovery if
necessary. If a fault has occurred in setting the new IP Address, the
ACU defaults to the original 192.168.129.51 address.