EasyManua.ls Logo

Baumuller b maXX 3000 - Safety Levels and Safety Notes

Baumuller b maXX 3000
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Optional safety function STO of BM3300
Instruction handbook b maXX BM3000, BM3200, BM3300
Document no. 5.11018.11 Baumüller Nürnberg GmbH
152
of 218
8.5
8.5.2 Safety levels and safety notes
Type code BM3300 with safety function STO (Safe Torque Off):
BM33XX-XXXX-XXXXX[-X]-XXXXX[-S00
]-XX[-XX][-EXX][-#XX]
Safety version optional
S00: Safety function STO
There is no conformity to the safety standards.
Permitted for process protection only.
S01: Safety function STO
Safety claim PLe / SIL3 (for replacement only)
S02: Safety function STO
Safety claim PLe / SIL3
with short-circuit detection (standard type)
according EN ISO 13849-1 and EN 62061
The Baumüller compact servo unit
BM33XX-XXXX-XXXXX[-X]-XXXXX-S01/S02-XX[-XX][-EXX][-#XX]
provides the safety function STO (Safe Torque Off).
m The drive is without torque in STO function.
m The activation of the power amplifier is reliable disabled.
m The STO function fulfills the stop category 0 according EN 60204-1.
If no load is active on the motor shaft, the drive will coast to a standstill. For this reason
no active danger is caused by the drive in case of an enabled STO function. A restart of
the drive is not possible without a reset of the STO function.
NOTE!
Devices with the approval mark of TÜV Rheinland and the Safety label provide a cer-
tified safety function, only, refer to ZPage 22.

Table of Contents