Cables
Instruction handbook b maXX BM3000, BM3200, BM3300
Document no. 5.11018.11 Baumüller Nürnberg GmbH
180
of 218
11.1
11.1.4 Cable DC-link
Device Cross-section Connection at Device
BM3X0X
BM3X1X
2 x 1 to 2.5 mm
2
(AWG 18 - 14)
flexible cable with/without wire end ferrule
(screw
contact)
11.1.5 Cable control power supply / signals
Cross-section
1)
1.5 mm
2
Maximum length (without digital IO)
2)
optional
Maximum length digital IO 30 m
Connection at device Without/with wire end ferrules
(plug-in terminal
1)
The laying procedure is not specified.
2)
The length of the cable in order to comply with the EMC-regulation is irrelevant.
HINWEIS!
A ferrite core (part No. 308293) must be used with a DC link connection longer than
3 m to ensure a reliable EMC interference immunity of the BM3000, BM3200,
BM3300. The DC link cables connected with 1C1 and 1D1 must be led through the
ferrite core with 3 turns per cable. The ferrite core should be close to the connection
X205 of the BM3000, BM3200, BM3300.