Electrical data
Instruction handbook b maXX BM3000, BM3200, BM3300
Document no. 5.11018.11 Baumüller Nürnberg GmbH
36
of 218
3.4
3.4.2 Electrical data BM3X01-XT/BM3X11-XT
BM3X01
3-phase/3 x 400 V
BM3X01
1-phase/1 x 400 V
Input rated power output
1)
4.2 kVA 3.9 kVA
Input rated current (I
eff
)
1) 2) 3)
6 A 5.6 A
Distortion factor of the input current (THD
I
)
1)
118 % 130 %
Input peak current (I
eff
)
1) 2) 3)
10.4 A 5.6 A
DC-link voltage power supply-dependent/rating 540 V
DC
DC-link capacitance (internal) 235 µF
DC-link capacitance (external) see DC link connection of additional capacities
fr
om ZPage 116
DC-link discharge time (internal DC-link capacitance) ca. 450 s
Output voltage
(U
AC
)
1) 4)
0 ... 400 V
Output frequency at 4 kHz
5) 6)
0 ... 450 Hz
Output rated current
(I
AC
)
1)4)7)8)9)
at 2 kHz
5)
5 A 2 A
Output rated current (I
AC
)
1)4)7)8)9)
at 4 kHz
5)
5 A 2 A
Output rated current
(I
AC
)
1)4)7)8)9)
at 8 kHz
5)
3.5 A 2 A
Output rated current (I
AC
)
1)4)7)8)9)
at 16 kHz
5)
2.5 A 2 A
Output peak current (I
AC
)
1)4)7)8)9)
at 2 kHz
5)
10 A 2 A
Output peak current
(I
AC
)
1)4)7)8)9)
at 4 kHz
5)
10 A 2 A
Output peak current (I
AC
)
1)4)7)8)9)
at 8 kHz
5)
7 A 2 A
Output peak current
(I
AC
)
1)4)7)8)9)
at 16 kHz
5)
5 A 2 A
Max. peak current time 60 s
Break resistor start-up voltage 785 V
Break resistor peak power 1200 W for max. 150 ms
Average ballast power 100 W
Switch on ready-to-operate after 4 s
Max. upload time 0.5 s
Power loss referring to power connection 70 W 50 W
Power loss referring to control voltage max. 30 W
Cooling air requirement 11 m
3
/h
with internal ballast resistor BM3X01-XTXX-XXXXX-B-X
XXXX-
Footnotes see ZPage 43.

Table of Contents