9.3
9.3 Inspection intervals - maintenance notes
Preventive maintenance is prescribed to keep the device in an optimum operating condi-
tion and ensure a long service life. It is recommended to have inspections performed reg-
ularly by qualified personnel.
Daily
inspection:
Basic check points as to whether discrepancies have occurred during operation:
m Does the motor work as requested?
m Is the operating environment normal?
m Is the cooling system working normal?
m Is there an unusual vibration or noise during operation?
m Does the motor overheat during operation?
Regularly
scheduled
inspection:
Before inspection, switch off the input voltage and wait until the device's capacitors have
discharged.
DANGER!
Risk of fatal injury from electrical current!
Therefore:
m Switch off voltage before performing work!
m Only qualified personnel may mount, install and maintain the devices.
m Please remove all metallic objects worn, such as watches or rings, for example,
before beginning to work on the device.
m Insulated tools are permitted, only.