Identification of the device
Instruction handbook b maXX BM3000, BM3200, BM3300
Document no. 5.11018.11 Baumüller Nürnberg GmbH
54
of 218
4.2
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Fieldbus interface
1: EtherCAT
®
CoE
2: VARAN
3: CANopen
®
4: POWERLINK
®
5: ProfiNET RT/IRT
7: EtherCAT
®
SoE
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Encoder interface
1: HIPERFACE
®
, EnDat
®
2.1, SSI,
square and sine incremental encoder,
resolver
2: EnDat
®
2.2
3: HIPERFACE DSL
®
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Digital inputs/outputs
1: 2 digital inputs/ 2 digital outputs
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Analog inputs/outputs
1: 1 analog input/ 2 analog outputs
signal bus for max.12 devices
2: 2 analog inputs/2 analog outputs
extended signal bus for max. 30 devices
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Option inputs/outputs
0: no
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Kind of STO function optional
(only BM3300)
S00: Safety function STO
Note:
Not conform to Safety Standards.
Permitted for process protection only.
S01: Safety function STO according
Safety claim PLe / SIL3
(for replacement only)
S02: Safety function STO according
Safety claim PLe / SIL3
with short-circuit detection
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Incompatible controller software version
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Option compatible controller software
version
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Software function option
BM3XXX-XXXX-XXXXX[-X]-XXXXX[-S0X]-XX[-XX][-EXX][-#XX] Safety level option (only BM3300)
#00: Used for safety level STO