TABLE 120 ICX 7450 system-max values without uRPF conguration
System parameter Default Maximum Current Congured
ip-route 12000 15168 12000 12000
ip6-route 5120 5120 5120 5120
ip-route-default-vrf 12000 15168 12000 12000
ip6-route-default-vrf 5120 5120 5120 5120
ip-route-vrf 1024 15168 1024 1024
ip6-route-vrf 100 5120 100 100
TABLE 121 ICX 7450 system-max values with uRPF conguration after reload
System parameter Default Maximum Current Congured
ip-route 6000 7584 6000 6000
ip6-route 2584 3572 2584 2584
ip-route-default-vrf 6000 7584 6000 6000
ip6-route-default-vrf 2560 2560 2560 2560
ip-route-vrf 512 7584 512 512
ip6-route-vrf 50 2560 50 50
Enabling unicast Reverse Path Forwarding
Unicast Reverse Path Forwarding can be enabled in dierent modes.
The strict mode is enabled when you enable uRPF on ICX 6610 devices. The prexes learned over the VE interfaces that do not have
tunnel-termination specied as a next hop are enabled. On ICX 7750 devices, the uRPF check enables the interface level CLI and
hardware settings. You should reload the device after enabling reverse path check for this conguration to be captured in the system
settings.
NOTE
Refer to the FastIron Command Reference for a complete list of supported commands.
1. Enter global conguration mode.
2. Enter the reverse-path-check command.
The following example enables uRPF at the global level.
device(config)# reverse-path-check
Conguring unicast Reverse Path Forwarding modes
Congure the various unicast reverse path forwarding modes on a layer 3 VE or physical interface.
You must enable unicast reverse path forwarding globally before you enable the required forwarding modes.
1. Enter interface conguration mode.
2. Enter the rpf-mode command followed by the required mode (strict or loose) you want to congure on the device. You can
optionally use the exclude default route (urpf-exclude-default) check on the physical interface.
Enabling unicast Reverse Path Forwarding
FastIron Ethernet Switch Layer 3 Routing
592 53-1003627-04

Table of Contents

Other manuals for Brocade Communications Systems FastIron X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron X Series and is the answer not in the manual?

Brocade Communications Systems FastIron X Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron X Series
CategorySwitch
LanguageEnglish

Related product manuals