TABLE 107 show ip vrrp vrid output description (continued)
Field Description
current dead interval The current value of the dead interval. This value is equal to the value
congured for the dead interval.
If the value for the dead interval is not congured, then the current dead
interval is equal to three times the Hello interval plus Skew time (where
Skew time is equal to 256 minus priority divided by 256).
NOTE
This eld does not apply to VRRP
Owners.
preempt mode Whether the backup preempt mode is enabled. If the backup preempt
mode is enabled, this eld contains "true". If the mode is disabled, this eld
contains "false".
advertise backup Whether Backup routers send Hello messages to the Master.
Displaying statistics
You can view VRRP and VRRP-E detailed or summary statistics.
Displaying detailed statistics
Use the stat keyword to display detailed statistics.
The following example displays the output of the show ip vrrp stat ve command:
device# show ip vrrp stat ve 105
Interface ethernet v105
rxed vrrp header error count = 0
rxed vrrp auth error count = 0
rxed vrrp auth passwd mismatch error count = 0
rxed vrrp vrid not found error count = 52
VRID 55
rxed arp packet drop count = 0
rxed ip packet drop count = 0
rxed vrrp port mismatch count = 0
rxed vrrp number of ip address mismatch count = 0
rxed vrrp ip address mismatch count = 0
rxed vrrp hello interval mismatch count = 0
rxed vrrp priority zero from master count = 0
rxed vrrp higher priority count = 0
transitioned to master state count = 1
transitioned to backup state count = 1
total number of vrrp packets received = 4
backup advertisements received = 1
total number of vrrp packets sent = 25
backup advertisements sent = 1
VRID 105
rxed arp packet drop count = 0
rxed ip packet drop count = 0
rxed vrrp port mismatch count = 0
rxed vrrp number of ip address mismatch count = 0
rxed vrrp ip address mismatch count = 0
rxed vrrp hello interval mismatch count = 0
rxed vrrp priority zero from master count = 0
rxed vrrp higher priority count = 1
transitioned to master state count = 1
transitioned to backup state count = 2
total number of vrrp packets received = 455
backup advertisements received = 0
total number of vrrp packets sent = 105
backup advertisements sent = 10
Displaying VRRP and VRRP-E information
FastIron Ethernet Switch Layer 3 Routing
550 53-1003627-04

Table of Contents

Other manuals for Brocade Communications Systems FastIron X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron X Series and is the answer not in the manual?

Brocade Communications Systems FastIron X Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron X Series
CategorySwitch
LanguageEnglish

Related product manuals