EasyManua.ls Logo

Canon imagePROGRAF iPF6400S - Specifications; Spectrophotometer Unit Specifications

Canon imagePROGRAF iPF6400S
1022 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spectrophotometer Unit Specifications
Spectrophotometer Unit Specifications
Specifications
Specifications
Important
The following values may vary depending on the operating environment.
Spectrophotometer Sensor
Model name X-Rite ILS25
Measurement geometry conditions 0°/45° ANSI/ISO 5-4
Illumination Tungsten lamp with UV cut filter + UV-LED
Measurement aperture Diameter 3.55 mm
Spectral Output 31 points (400nm to 700nm 10nm gap)
Observer Angle 2°/10°
Illumination Type A, C, D50, D55, D65, D75, F2, F7, F8, F10, F11, F12
Measurement Range 0 to 150% reflection
Repetition Accuracy Maximum dEcmc0.2 (White tile)
Maximum dEcmc0.6 (Black tile)
Instrument Error Average dEcmc0.5 (BCRA tile 12 color)
Max dEcmc ≤ 1.0 (12-color BCRA tiles)
Recommended calibration frequency Once per year
Specifications
iPF6400S
User's Guide
Specifications
Spectrophotometer Unit
Specifications
1000

Table of Contents

Other manuals for Canon imagePROGRAF iPF6400S

Related product manuals