Sets the display brightness of panel.
CONFigure:BRIGhtness <Arg>
CONFigure:BRIGhtness HIGH
Sets the device to Master. This command is not required for the
Slave device.
CONFigure:MSTSLV:ID <Arg>
CONFigure:MSTSLV:ID MASTER
MASTER | SLAVE1 | SLAVE2 | …… | SLAVE9
CONFigure:MSTSLV? must be OFF when setting it. (Not in series/parallel mode.)
13. CONFigure:MSTSLV:PARSER
Sets to series or parallel mode. Both Master and Slave need to be
set by this command.
CONFigure:MSTSLV:PARSER <Arg>
CONFigure:MSTSLV:PARSER PARALLEL
CONFigure:MSTSLV? must be OFF when setting it. (Not in series/parallel mode.)
14. CONFigure:MSTSLV:NUMSLV
Sets the number of SLAVE to be controlled. This command is not
required for the Slave device.
CONFigure:MSTSLV:NUMSLV <NR1>
CONFigure:MSTSLV:NUMSLV 1
1. CONFigure:MSTSLV? must be OFF when setting it. (Not in series/parallel mode.)
2. Only 1 slave can be set when in series mode and maximum 3 slaves can be set
when in parallel mode.
3. Keypro is required for series connection, so be sure to connect it first in series mode.
Release and remove the keypro when operating standalone or in parallel mode.