Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
5-26
13. PROGram:SEQuence:CURRent:SLEW
Sets the sequence of current slew rate for the output in List mode.
PROGram:SEQuence:CURRent:SLEW <NRf+>
PROG:SEQ:CURR:SLEW? [{MAX/MIN}]
Source and Load current share this setting.
14. PROGram:SEQuence:CURRent:LOAD
Sets the sequence for Load current output in List mode.
PROGram:SEQuence:CURRent:LOAD <NRf+>
PROG:SEQ:CURR:LOAD? [{MAX/MIN}]
15. PROGram:SEQuence:TIME
Sets the duration of the sequence in List mode.
PROGram:SEQuence:TIME <NRf+>
PROG:SEQ:TIME? [{MAX/MIN}]
Clears all sequences from the program selected in List mode.
Adds sequences to the program selected in List mode.
1~100 (based on the remaining sequence no. for configuration)
PROGram:ADD? (It returns the configurable sequence no.)
85 –it indicates the remaining no. is 85.