Remote Operation
5-25
Syntax:
PROGram:PULL <ARG>
Parameter:
<ARG>: LOW | HIGH
Example:
PROGram:PULL LOW
Query Syntax:
PROGram:PULL?
Return Parameter:
LOW | HIGH
Query Example:
PROGram:PULL?
Return Example:
LOW
8. PROGram:SEQuence:SELected
Description:
Sets the execution sequence of a program in List mode.
Syntax:
PROGram:SEQuence:SELected <NR1>
Parameter:
1 to the sequence no. of present program.
Example:
PROG:SEQ:SEL 3
Query Syntax:
PROGram:SEQuence:SELected? [{MAX/MIN}]
Return Parameter:
<NR1>
Query Example:
PROG:SEQ:SEL?
Return Example:
3
9. PROGram:SEQuence:TYPE
Description:
Sets the action type of a sequence in List mode.
Syntax:
PROGram:SEQuence:TYPE <Arg>
Parameter:
<Arg> AUTO | MANUAL | TRI | SKIP
Example:
PROG:SEQ:TYPE AUTO
Query Syntax:
PROG:SEQ:TYPE?
Return Parameter:
AUTO | MANUAL | EXT.TRIGGER | SKIP
Query Example:
PROG:SEQ:TYPE?
Return Example:
AUTO
10. PROGram:SEQuence:VOLTage
Description:
Sets the sequence for voltage output in List mode.
Syntax:
PROGram:SEQuence:VOLTage <NRf+>
Parameter:
<NRf+>
Example:
PROG:SEQ:VOLT 40.5
Query Syntax:
PROG:SEQ:VOLT? [{MAX/MIN}]
Return Parameter:
<NRf+>
Query Example:
PROG:SEQ:VOLT?
Return Example:
4.050000e+01
11. PROGram:SEQuence:VOLTage:SLEW
Description:
Sets the sequence of voltage slew rate for output in List mode.
Syntax:
PROGram:SEQuence:VOLTage:SLEW <NRf+>
Parameter:
<NRf+>
Example:
PROG:SEQ:VOLT:SLEW 1
Query Syntax:
PROG:SEQ:VOLT:SLEW? [{MAX/MIN}]
Return Parameter:
<NRf+>
Query Example:
PROG:SEQ:VOLT:SLEW?
Return Example:
1.000000e+01
12. PROGram:SEQuence:CURRent
Description:
Sets the sequence for Source current output in List mode.
Syntax:
PROGram:SEQuence:CURRent <NRf+>
Parameter:
<NRf+>
Example:
PROG:SEQ:CURR 45
Query Syntax:
PROG:SEQ:CURR? [{MAX/MIN}]