EasyManua.ls Logo

Chroma 62000D Series - Page 96

Chroma 62000D Series
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
3-44
4. Next, tap “START” next to “I source point 2 to perform the second point current
calibration. The DC power supply will output a current of approximately 60.00A. Enter
the accrual current measured by across the current shunt and enter into box for position
[2] and tap “SEND” to confirm.
5. Repeat above for “I source point 3”. The DC power supply will output a current of
approximately 108.00A. Enter the current measured across the current shunt and enter
into position [3] entry box and tap “SEND” to confirm.
Figure 3-68
Next perform calibration of negative current points 1, 2 and 3 by following the above
procedure and following display prompts. Calibration points will be -12A, -60A and -108A.
Figure 3-69