Appendix A      System Error Messages
Error Message and Recovery Procedures
A-6
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
78-6511-05
CMP-5-REMOVE The Device is removed from the cluster (Cluster 
Name:[chars]) 
Explanation
The message means that the device is removed from the cluster: 
[chars] is the cluster name.
Action   No action is required.
Environment Messages
This section contains the Environment error messages.
ENVIRONMENT-2-FAN_FAULT
Explanation
This message means that an internal fan fault is detected. This 
message is available only on the Catalyst 3524-PWR XL switch.
Action   Either check the switch itself, or use the show env privileged EXEC 
command to check if a fan on the switch has failed. The 
Catalyst 3524-PWR XL switch can operate normally with one failed fan. 
Replace the switch at your convenience.
ENVIRONMENT-2-OVER_TEMP
Explanation
This message means that an overtemperature condition is 
detected. This message is available only on the Catalyst 3524-PWR XL 
switch.
Action   Use the show env command to check if an overtemperature condition 
exists. If it does:
• Place the switch in an environment that is within 32 to 113°F (0 to 45°C).
• Make sure fan intake and exhaust areas are clear.
If a multiple-fan failure is causing the switch to overheat, replace the switch.