A-5
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
78-6511-05
Appendix A      System Error Messages
Error Message and Recovery Procedures
Error Message and Recovery Procedures
This section lists the switch system messages by facility. Within each facility, the 
messages are listed by severity levels 0 to 7: 0 is the highest severity level, and 7 
is the lowest severity level. Each message is followed by an explanation and a 
recommended action.
Chassis Message
This section contains the Chassis error message.
CHASSIS-5-BLADE_EXTRACT
Explanation
The message means that the hot-swap switch has been pressed.
Action   Extract the module.
CMP Messages
This section contains the Cluster Membership Protocol (CMP) error messages.
CMP-5-ADD: The Device is added to the cluster (Cluster 
Name:[chars], CMDR IP Address [inet])
Explanation The message means that the device is added to the cluster: [chars] 
is the cluster name, and [inet] is the Internet address of the command switch.
Action   No action is required. 
CMP-5-MEMBER_CONFIG_UPDATE: Received member configuration from 
member [dec] 
Explanation
This message means that the command switch received a member 
configuration: [dec] is the member number. 
Action   No action is required.