GR740-UM-DS, Nov 2017, Version 1.7 362 www.cobham.com/gaisler
GR740
30.3.8 Configuration lockdown register
Table 462.0x20 - LOCKDOWN - Configuration lockdown register
31 24 23 16 15 8 7 0
RESERVED PERMANENT RESERVED REVOCABLE
0000
rrw*r rw
31: 24 RESERVED
23: 16 Permanent lock bit mask (PERMANENT) - Bit N for register at offset 4*N, 1=locked, 0=unlocked
Bits that are set to 1 in this field can only be cleared with a full system reset.
15: 8 RESERVED
7: 0 Revocable lock bit mask (REVOCABLE) - Bit N for register at offset 4*N, 1=locked, 0=unlocked