EasyManua.ls Logo

COBHAM GR740 - Page 426

COBHAM GR740
488 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GR740-UM-DS, Nov 2017, Version 1.7 426 www.cobham.com/gaisler
GR740
Table 557. 0x10 - SPW2.DKEY - Destination key
31 87 0
RESERVED DESTKEY
0x000000 0x00
rr
31: 8 RESERVED
7: 0 Destination key (DESTKEY) - RMAP destination key.
Table 558. 0x14 - SPW2.TC - Time-code
31 8765 0
RESERVED TCTRL TIMECNT
0x000000 0x0 0x00
rrwrw
31: 8 RESERVED
7: 6 Time control flags (TCTRL) - The current value of the time control flags. Sent with time-code resulting
from a tick-in. Received control flags are also stored in this register.
5: 0 Time counter (TIMECNT) - The current value of the system time counter. It is incremented for each tick-in
and the incremented value is transmitted. The register can also be written directly but the written value will
not be transmitted. Received time-counter values are also stored in this register.

Table of Contents