CRS-300 1:10 Redundancy Switch MN/CRS300.IOM
Modem, RMI/TMI, and Switch Configuration Revision 19
5–29
Use the CRS-300 Front Panel menu to set the Restore Holdoff Period. Do these steps:
Step
Task
1
Use the [←][→] keys to select the nested CONFIG: OPTIONS HOLDOFFS menu.
2
Change the RESTORE HOLDOFF to any number in the range of 1 to 99 seconds.
5.6.2.6 Set the Alarm Masks
Another way to adjust the Switch's reaction in AUTO mode is to mask modem faults. You may
disable modem Rx, Tx or both fault types so that the Switch does not react to them. This
masking prevents the Switch from taking automatic action and prevents the logging of the faults
in the stored events list.
These masks are global to all the modems attached to the Switch.
Use the CRS-300 Front Panel menu to set the Alarm Masks. Do these steps:
Step
Procedure
1
Use the [←][→] keys to select the nested CONFIG: OPTIONS MASKS MODEM-ALARMS
menu.
2
Set the mask parameters as desired.
In the event that a second fault occurs, another way to influence Switch behavior is via Priority
Mode. For detailed information on Priority Mode, see Sect. 6.2.2.3.1 CONFIG: OPTIONS
PRIORITY
.

Table of Contents