CRS-300 1:10 Redundancy Switch MN/CRS300.IOM
Introduction Revision 19
1–10
1.3.3.3 Modem Interface Cards
1.3.3.3.1 CDM-625/A, CDM-570/A, CDM-570L/AL, CDM-600/L Interface
Cards
The following tables indicate which TMI (Traffic Modem Interface) cards and which RMI
(Redundant Modem Interface) cards should be used with each modem and data type:
CDM-625/A Modem
Data Type
TMI Type
RMI Type
EIA-422, V.35
CRS-316
Notes 5, 6
CRS-310
10/100 Ethernet
Note 4
ASI
Notes 5, 6
CRS-325
Notes 5, 6
G.703 Bal (DDI, IDO, DDO, IDI)
Note 2
G.703 Unbal
Note 2
G.703 Bal (DDI, IDO, DDO, IDI)
Note 2
G.703 Unbal (DDI, IDO, DDO, IDI)
Note 2
CRS-330
HSSI
10/100 Ethernet
Note 4
CRS-336
Notes 5, 6
EIA-422, V.35, LVDS
CRS-340
Note 3
G.703 Bal (DDI, IDO, DDO, IDI)
Note 2
G.703 Unbal
Notes 1, 2
Quad E1
CDS-365D
Notes 5, 6
CDM-570/A, CDM-570L/AL Modems
Data Type
TMI Type
RMI Type
G.703 T1/E1 Bal/Unbal
CRS-330 or CRS-340
CRS-310
EIA-422, V.35, EIA-232
CRS-340
CDM-600/L Modems, CDM-625/A Modem (in CDM-600 Emulator Mode)
Data Type
TMI Type
RMI Type
G.703 Bal (DDI, IDO, DDO, IDI)
Notes 1, 2
G.703 Unbal (DDI, IDO, DDO, IDI)
Notes 1, 2
CRS-330
CRS-310
EIA-422/V.35, EIA-232, LVDS
CRS-340
Note 3
G.703 Bal (DDI, IDO, DDO, IDI)
Notes 1, 2
G.703 Unbal
Notes 1, 2
Converts LVDS (Modem) to/from HSSI (User)
CRS-370
Notes:
1) For CDM-600/L modem to switch data (Bal and Unbal) use a DB-15 to DB-15 data cable.
2) For CDM-625/A modem to switch data (Bal and Unbal) use a DB-9 to DB-15 data cable.
3) As of September 2008, the CRS-320 TMI is obsolete. Use the CRS-340 TMI in its place.
4) For CDM-625/A where the terrestrial data type is Ethernet, you can use only one of any
four Ethernet ports on the CDM-625/A rear panel in Ethernet Bridge Mode.
5) From Redundant Modem to RMI, use a DB-25 to DB-25 Control cable.
6) From Traffic Modem to TMI, use a DB-9 to HD-15 Control cable.

Table of Contents