CRS-300 1:10 Redundancy Switch MN/CRS300.IOM
Switch Connectors and Pinouts Revision 19
3–7
3.2.2 TMI User Data Connectors
3.2.2.1 EIA-232/422/V.35 Connector, DB-25F (CRS-316)
See Table 3-4 for the pinouts of the DB-25F EIA-232/422/V.35 User Data Interface connector – “J2”
on the CRS-316 TMI.
Table 3-4. EIA-232/422/V.35 Connector
Internal Transmit Clock ‘B’
Note 1
20 Note 2
19
Request to Send ‘B’ /
DTE to Modem
RS B RS B
4
Request to Send ‘A’ /
Ready for Receiving ‘A’
DTE to Modem
RS A RS A
3 Receive Data ‘A’ Modem to DTE 104 RD A BB RD A
Internal Transmit Clock ‘A’
2 Transmit Data ‘A’ DTE to Modem 103 SD A BA SD A
1 Shield --- 101 Shield AA FG
1) “Receiver Ready” is an EIA-232-level control signal on a V.35 interface.
2) Do NOT connect signals to these pins – they are reserved for use by the redundancy system.
3) 'B' signal lines are not used for EIA-232 applications.
4) For X.21 operation, use the EIA-422 pins, but ignore Receive Clock if the modem is DTE, and ignore Transmit clocks if the modem is DCE.