PS8149KENAA01 15/09/2004 Page 215
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
LEVEL 2 BREAK
- WITH HOLD CALL NO YES.
- ALARM REPORTED AFTER Enter a duration (in sec).
- PBX RECOVERY NO YES.
- AFTER ALARM MONITORING Enter a duration (in sec).
NUMBER OF SUCCESSIVE TRANSITS 2 digits
CHARGING DISPLAY MODE NO YES.
- INFORMATION TYPE 4 CHARACTERS
- IDENTIFIER LENGTH 2 digits
- START IDENTIFIER 2 CHARACTERS
- LOCATED 4 CHARACTERS
USER TO USER INFORMATION (SUU) NO YES.
TRT MESSAGE STATUS NO YES.
TIME-OUT T301 TO T322 Enter a duration (in sec).
Note: The default values vary depending on the signalling, and are recorded in a table
(they cannot be accessed).
T301 T302 T303 T304 T305 T308 T309 T310 T313 T316 T322
ISDN
100 20 10 60 4 4 60 60 4 120 5
QSIG
180 15 5 20 4 4 90 90 4 120 5
ETSI
100 15 4 30 30 4 60 40 4 120 5
1TR6
100 20 4 60 30 4 60 80 4 120 5
REMOTE TONE MONITORING
- FLAG PROGRESSION 1 TO 8 NO YES
FOR THE SIGNALLING
ISDN: T0 VN2+_T0 VN2+_T2
Select the line signalling.