PS8149KENAA01 15/09/2004 Page 69
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
3.6 PARAMETER MANAGEMENT (MENU 3-6)
For the Call Manager (F5): Menu 3-4 (Parameter management).
PARAMETER MANAGEMENT
MULTI-COMPANY MANAGEMENT YES
- TEL. CALL BETWEEN COMPANIES YES
- DATA CALL BETWEEN COMPANIES NO
MULTI-SITE MANAGEMENT YES
OPERATOR GROUP AUDIT ACTIVATED NO
TYPE OF WIRELESS MANAGEMENT DECT
CONSOLE TIME-OUT (SECONDS) 600
CURRENT LANGUAGE LANGUAGE 1
INSTALL. NAME ..............
NUMBER OF RECORDS (current) (requested)
- TELEPHONY TYPE 1956
- DATA TYPE 10 10..
- SERVICE TYPE 10 10..
- SUPERVISION TYPE 24 24..
- OBSERVATION TYPE 40 40..
-------------------------------------------
Figure 40: Menu 3-6 (Parameter management).
This menu is used to define management and the desired language.
MULTI-COMPANY MANAGEMENT
NO YES
Select YES to display all the multi-company menus.
On start up, the system is configured in single-company configuration.
Note: If you select NO, the single-company configuration characteristics are re-
established:
no company other than company 0
no department other than department 0 of company 0
no routing code other than code 0
no abbreviated number code other than code 0
If you select these conditions, you will have to make other modifications before
you can delete the created names.
This field is only changed from YES to NO in very rare circumstances.