5.7.2 GLOBAL RESET (MENU 5-7-2)
For the Call Manager (F5): Menu 5-4-2 (Global reset)
ALARMS CONFIGURATION RESET
DETECTION IN LOCAL SITE
REPORTED TO SET NOT TRANS.
REPORTED TO KEY NOT TRANS.
REPORTED TO TICKET NOT URGENT
REPORTED TO CENTRAL. NOT URGENT
REPORT TO X25 ADDRESS NOT TRANS.
RESET CONFIRMATION YES
----------------------------------------
Figure 213: Configure the alarms: global reset
This reset menu is used to define default processing for all LSB groups and alarms.
DETECTION IN
LOCAL SITE ANOTHER SITE
Select the local site if the reset is for alarms detected locally, or another site if the reset is
for alarms detected in other sites and due to centralisation of the logbook.
Note: This field only appears in multi-site configuration.
REPORTED TO SET / KEY / TICKET / CENTRAL.
KEYING NOT TRANS. NOT URGENT URGENT
ADDRESS 1 ADDRESS 2 TO 2 ADDR
Define for each output the default processing for all LSB groups and alarms.
REPORT TO X25 ADDRESS
NOT TRANS. ADDRESS 1 ADDRESS 2 TO 2 ADDR
Define for the X.25 Address output the default processing for all LSB groups and alarms.
RESET CONFIRMATION
YES NO
Select YES to reset and press Enter to confirm.