Enter/Exit Programming Mode GS1 DataBar
TM
Expanded
126
Touch TD1100
GS1 DataBar Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding for the GS1
DataBar Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
GS1 DataBar Expanded Set Length 1
This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Control.
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in
Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 74 characters. See "Set Length 1" on page 278 for more detailed
programming instructions.
$CXBLC00
GS1 DataBar Expanded Length Control = Variable
Length
$CXBLC01
GS1 DataBar Expanded Length Control = Fixed Length
DEFAULT
$CXBL1
Select GS1 DataBar Expanded Set Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from the
Alphanumeric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning the ENTER/
EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the begin-
ning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character