Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms
increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
leading ze
roes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode
.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix D, Keypad
representing the
duration which was determined in the steps above. Y
ou will hear a two-beep indication
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See the table below for examples of how to set this feature.
Table 17. Good Read LED Duration Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
Good Read LED
stays on until
next trigger pull
(00)
200ms
1500ms (1.5
sec
.)
25
00ms (2.5 sec.)
2
Divide by 100 (and pad with
leading zer
oes)
000 002 015 025
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘0’ ‘0’, ‘0’ and ‘2’ ‘0’, ‘1’ and ‘5’ ‘0’, ‘2’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic Touch 90 pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Touch 90 pro and is the answer not in the manual?

Datalogic Touch 90 pro Specifications

General IconGeneral
Scan speed256 sec/page
Decoding standards2/5 family, Code 39, Code 32, Code CIP 39, Code 128, EAN128, EAN/UPC, ISBN/ISSN, CODABAR, Code 93, ISBT128, MSI, Plessey, Telepen, Delta IBM, Code 11, Code 49, Code 16K, GS1 Databar
Standard interfacesUSB, RS-232
Input voltage5 V
Power consumption150 mA
Dimensions (WxDxH)175 x 100 x 80 mm
Weight and Dimensions IconWeight and Dimensions
Weight195 g

Related product manuals