EasyManua.ls Logo

Datalogic Touch 90 pro

Datalogic Touch 90 pro
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Code 93 Enter/Exit Programming Mode
Product Reference Guide
223
Code 93 Set Length 2
This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length
does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See "Set Length 2" on page 280 for more detailed programming
instructions.
$CC9L2
Select Code 93 Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from the
Alphanumeric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning the ENTER/
EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the begin-
ning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Other manuals for Datalogic Touch 90 pro

Related product manuals