EasyManua.ls Logo

Datalogic Touch 90 pro

Datalogic Touch 90 pro
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode Code 39
138
Touch TD1100
Code 39 Set Length 1
This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the
minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length
does not include start/stop characters.
The length can be set from 0 to 50 characters. See "Set Length 1" on page 278 for more detailed
programming instructions.
$CC3L1
Select Code 39 Set Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from the
Alphanumeric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning the ENTER/
EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not
save the entry string. You can then start again at the begin-
ning.
~
CANCEL
DEFAULT
02 = Length 1 is 2 Characters

Table of Contents

Other manuals for Datalogic Touch 90 pro

Related product manuals