References RS-232 Parameters
258
Touch TD1100
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
To set the value:
1. Determine the desired character or value. A setting of 0xFF indicates the Disable Charac-
ter is not used (not available).
2. Use the
ASCII Chart
on the inside back cover of this manual to find the hex equivalent for
the desired character/value.
3. Go to
page 32
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter
Programming Mode.
4. Scan the bar code: SELECT DISABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric
characters fr
om the keypad in
Appendix D, Keypad
,
that represent the desired character/value determined above.
The second character will
cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode
.
This completes the procedure. See the table below for examples of how to set this feature.
Table 9. Disable Character Setting Examples
STEP ACTION EXAMPLES
1 Desired character/value
‘d ‘}’ ‘D’
Disable Command
Not Used
2 Hex equivalent from
ASCII Chart
0x64 0x7D 0x44 0xFF
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT DISABLE CHARACTER VALUE SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘6’ and ‘4’ ‘7’ and ‘D ‘4’ and ‘4’ ‘F’ AND ‘F’
6 Scan ENTER/EXIT PROGRAMMING MODE
NOTE
Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-
bit data is not recognized when the option
Data Bits
has been set as
7 Data Bits.