Enter/Exit Programming Mode Plessey
246
Touch TD1100
Plessey Set Length 2
This feature specifies one of the barcode lengths for Plessey Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length
does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only
one fixed length).
Table 3 provides examples for setting Length 2. See "Set Length 2" on page 280 for detailed
instructions on setting this feature.
Table 3. Plessey Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT PLESSEY LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the
entry string. You can then start again at the beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters