EasyManuals Logo

Datalogic Touch 90 pro User Manual

Datalogic Touch 90 pro
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #284 background imageLoading...
Page #284 background image
References Scanning Features
274
Touch TD1100
Scanning Features
Scan Mode
Selects the scan operating mode for the reader. Selections are:
Trigger Single:
When the trigger is pulled, scanning is activated until one of the following
occurs:
-
Scanning Active Time
has elapsed
- a label has been read
- the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is pulled,
scanning starts and the product scans until the trigger is released, or a label is read, or the
maximum
Scanning Active Time
has elapsed.
Trigger Hold Multiple :
When the trigger is pulled, scanning starts and the product scans until
the trigger is released or
Scanning Active Time
has elapsed. Reading a label does not disable
scanning.
Double Read Timeout
prevents undesired multiple reads of the same label while in this
mode.
Trigger Pulse Multiple:
When the trigger is pulled, continuous scanning is activated until
Scanning Active Time
has elapsed or the trigger has been released and pulled again.
Double Read
Timeout
prevents undesired multiple reads of the same label while in this mode.
Flashing:
The reader flashes
1
on and off regardless of the trigger status. Flash rate is controlled
by
Flash On Time
and
Flash Off Time
. When Flash is ON the reader reads continuously. When
Flash is OFF scanning is deactivated.
Always On:
No trigger pull is required to read a bar code. Scanning is continually on.
Double
Read Timeout
prevents undesired multiple reads of the same label while in this mode.
Stand Mode:
No trigger pull is required to read a bar code. Scanning turns on automatically
when an item is placed in reader's field of view. While in a stand watch state, the reader
illumination LED goes from dim to maximum bright.
1
Controlled by
Flash On Time
.

Table of Contents

Other manuals for Datalogic Touch 90 pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Touch 90 pro and is the answer not in the manual?

Datalogic Touch 90 pro Specifications

General IconGeneral
Scan speed256 sec/page
Decoding standards2/5 family, Code 39, Code 32, Code CIP 39, Code 128, EAN128, EAN/UPC, ISBN/ISSN, CODABAR, Code 93, ISBT128, MSI, Plessey, Telepen, Delta IBM, Code 11, Code 49, Code 16K, GS1 Databar
Standard interfacesUSB, RS-232
Input voltage5 V
Power consumption150 mA
Dimensions (WxDxH)175 x 100 x 80 mm
Weight and Dimensions IconWeight and Dimensions
Weight195 g