Dell Precision 7960 Tower - Rear-Nvme Module; Removing the Rear-Nvme Module

Dell Precision 7960 Tower
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Install the two screws (6-32) to secure the front-NVMe module to the flex1.
4. Connect the thermal-sensor cable and fan-controller cable to the connectors on the power-distribution board.
5. Connect the power cable (P5) and data cable to the connectors on the HSBP board.
NOTE:
Follow the same procedure to install the front-NVMe module into the flex0.
The HSBP power dongle-cable is required when both flex0 and flex1 is installed with NVMe module.
Next steps
1. Install the right-side cover.
2. Install the external solid-state drive assembly
3. Follow the procedure in After working inside your computer.
Rear-NVMe module
Removing the Rear-NVMe module
Prerequisites
1. Follow the procedure in Before working inside your computer.
2. Remove the external solid-state drive assembly.
3. Remove the right-side cover.
About this task
The following images indicate the location of the rear-NVMe module and provide a visual representation of the removal
procedure.