1. Align the screw holes on the rear-NVMe module with the screw holes on the flex4.
2. Place the rear-NVMe module into the slot in the flex4.
3. Install the two screws (6-32) to secure the rear-NVMe module to the flex4.
4. Connect the power cable and data cable to the connector on the HSBP board.
5. Connect the thermal-sensor cable and fan-controller cable to the connectors on the power-distribution board.
NOTE:
Follow the same procedure to install the rear-NVMe module into the flex3.
The HSBP power dongle-cable is required when both flex3 and flex4 is installed with NVMe module.
Next steps
1. Install the right-side cover.
2. Install the external solid-state drive assembly
3. Follow the procedure in After working inside your computer.