2.9  Load Cell Module Specifications  
2.9.1  General Specifications 
  AS02LC-A 
Rated supply voltage/Power 
24 VDC (-15 to +20%) / 5W 
18~31.2VDC 
Maximum current consumption 
Four-wire or six-wire load cell 
Expanding a temperature 
≤ ± 50 ppm/K v. E     
Reducing a temperature 
≤ ± 0.4 μV/K 
≤ 0.02% 
2.5, 10, 16, 20, 50, 60, 100, 200, and 400ms 
Eigenvalue applicable to a load 
0–1, 0–2, 0–4, 0–6, 0–20, 0–40 and 0–80 mV/V 
Maximum distance for 
100 meters 
Common-mode rejection ratio 
≥100 dB   
Extreme pulse value range 
1–100 (FW V1.04: 1 to 400) 
Isolation 
Between a digital circuit and the ground: 500 VAC   
Between an analog circuit and the ground: 500 VAC   
Between an analog circuit and a digital circuit: 500 VAC 
 