Category  Error Code  Description  How to fix them 
H’12010111  Adapter RPI not supported    3. Check the RPI for the adapter.   
H’12010113  Insufficient I/O connections 
1. Check if the number of connections exceeds the   
 limit. 
2. Reduce the number of the product connections.   
H12010119  
The connection of non-Listen 
only is not established. 
1. Check if the system has created the I/O   
  connections. 
2. Check the scanner I/O connection status. 
H’12010127  Incorrect adapter input size   
Check the module number and the product setup 
file to see if they match.   
H’12010128  Incorrect adapter output size 
Check the output size in the connection 
parameters. 
H’1201012D 
Consumed Tag does not 
exist. 
Check if the parameters in the Consumed tag are 
set correctly.   
H’1201012E  Produced Tag does not exist. 
Check if the parameters in the Produced tag are 
set correctly. 
H’12010204 
I/O connection connecting 
timeout   
No response from the adapter; check if the power 
and the network connection for the adapter are 
working properly.   
H’12010302 
Network bandwidth NOT 
available for data 
1. Check the I/O connection limit between the   
 scanner and the adapter. 
2. Increase the RPI value or reduce the number of   
 connections.   
H’12010315 
Incorrect adapter input/output 
instance   
Check the module number and the product setup 
file to see if they match.   
 
9.6.2.2 Application Error 
Category  Error Code  Description  How to fix them 
EtherNet/ 
IP Error 
H’00010203  I/O connection timeout   
1. Check the network connection status. 
2. Check if the module is working properly. 
3. Increase the RPI value. 
 
 