When Instance = 1, the Instance Attributes are listed below.
Instance
Attribute
Name
Access
Rule
Data Type Values Description
H’01 Status Get DWORD H’2
IP status, refer to the following *1
H’02
Configuration
Capability
Get DWORD H’15
Configuration capability, refer to
the following *2
H’03
Configuration
Control
Get/Set DWORD H’0
Configuration Control, refer to
the following *3
H’04
Physical Link
Object
Get
STRUCT of -- Path to physical link object
Path Size UINT H’0 Size of Path
Path EPATH --
Logical segments identifying the
physical link object
H’05
Interface
Configuration
Get/Set
STRUCT of --
TCP/IP network interface
configuration.
IP Address UDINT H’C0A80005
The devices IP address;
192.168.1.5
Network Mask UDINT H’FFFFFF00
The devices network mask:
255.255.255.0
Gateway Address UDINT H’C0A80001
Default gateway address:
192.168.0.1
Name Server UDINT 0 Primary name server
Name Server 2 UDINT 0 Secondary name server
Domain Name STRING 00 00 Default domain name
H’06 Host Name Get/Set STRING AS300T Device name
H’13
Encapsulation
Inactivity Timeout
Get/Set UINT 120
EIP device active connection
time;
unit:0-3600 seconds
When the device is communicating with the CPU module, the Instance Attribute H’03 and H’05 cannot be
written.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com

Table of Contents

Other manuals for Delta AS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AS Series and is the answer not in the manual?

Delta AS Series Specifications

General IconGeneral
SeriesAS Series
Power Supply24VDC
Cooling MethodNatural convection
Programming LanguageFunction Block Diagram (FBD)
Communication InterfaceEthernet, RS-232, RS-485
Output Voltage24V DC
Output Current2A
Operating Temperature55°C
Storage Temperature70°C
Protection FeaturesOvervoltage
CertificationsCE, UL

Related product manuals