AX-Series Motion Controller Instructions Manual Chapter 2
341
The example shows the behavior of DMC_ChangeMechanismGearRation.
Relevant parameters setting:
udiOutputRotation: udiInputRotation= 2: 1
udiPulsePerRotation: 10000 pulses
udiUnitsPerRotation: 20000 us
AxisType: 0 (rotary axis)
lrModulo: 360
Function block setting