Troubleshooting Guide
SmartDate X40 BFSE Version 1.0 Feb 2011
136/286
Operation Problems
1300
Cassette open
Close Cassette to clear fault
1301
User defined fault 1
User defined fault 1 raised via FlexIO input
1302
User defined fault 2
User defined fault 2 raised via FlexIO input
1303
User defined fault 3
User defined fault 3 raised via FlexIO input
1304
User defined fault 4
User defined fault 4 raised via FlexIO input
1305
User defined fault 5
User defined fault 5 raised via FlexIO input
1306
Print Go While Allocation complete
Clear allocation, select new job or update
current job
1307
Data queue overflow
Data for too many bags has been sent to the
SmartDate X40
1308
Data queue exhausted
There is no queued data to print. Insufficient
data has been sent to the SmartDate X40
before printing
File System Problems
1400
Corrupt file system
Reboot
1401
Failed to restore selected job
Select a new job to clear fault
1402
Failed to update job data
Cleared by operator action
1403
Variable data log file full
Retrieve the variable data log file or disable
variable data logging to continue printing
1404
Calendar file exhausted
Load new calendar file or select a job which
does not require a calendar file
1405
Failed to Restore Job Queue
Items in the job queue were not successfully
restored at power-up
1406
Failed to Parse Ribbon Definitions file
‘Ribbons.defcodes’ file is incorrectly formatted.
Either restore to factory or download a good
version