Troubleshooting Guide
SmartDate X40 BFSE Version 1.0 Feb 2011
174/286
Type telnet 10.0.0.15 20000 (10.0.0.15 is the
default SmartDate X40 IP address)
A successful connection will result in some XML
being sent back to the PC such as:-
<Envelope><Header sender=’Actor1’
receiver=‘></Header><Body><Ping act=’31944’><
/Ping></Body></Envelope><Envelope><Header
sender=’Actor1’ receiver=‘></Header><
Body><Ping
act=’31945’></Ping></Body></Envelope><Envelop
e><Header sender=’Actor1
‘ receiver=‘></Header><Body><Ping
act=’31946’></Ping></Body></Envelope>
No reply, or one that is not similar to the above
indicates that the port is being blocked (e.g.
firewall).
Communication settings Page
97
9 Controller
Ö
Replace the Controller PCB or
replace the Controller.
Ö
Replacing the Controller PCB Page 228
Repl
acing the Controller Refer to the Users Manual