MAINTENANCE, SERVICE AND FAULT FINDING
4-56 25364 Issue 8 March 2018
1406 Init Serial port Could not open serial port. Try to
reopen the port by switching baud rate.
1407 Read Timeout The start of a command was read, but
the remainder of the command was not
received within a period of time. Check
the sending device.
1408 Memory Allocation
Failed
Could not allocate enough memory.
1409 Write Timeout The receiver does not accept data.
Check cable.
1410 Invalid Handle The internal handle used for the
transmission is invalid. Either the port
was not opened properly or another
device is blocking the port.
1411 Error Creating send
block
Any transmission is sent in blocks. One
such block could not be created.
Check transmission.
1412 Error Reading String A string was supposedly sent but the
receiver could not recognise the
format.
Check transmission. Lower the baud
rate. Enable Hardware handshake.
1413 Error Reading Integer An integer was supposedly sent but
the receiver could not recognise the
format.
Check transmission. Lower the baud
rate. Enable Hardware handshake.
1414 Error Reading Double A floating point number was
supposedly sent but the receiver could
not recognise the format.
Check transmission. Lower the baud
rate. Enable Hardware handshake.
1415 Error Reading data A block of raw data was supposedly
sent but the receiver could not
recognise the format.
Check transmission. Lower the baud
rate. Enable Hardware handshake.
1416 Version Conflict The software in the unit or the external
device is too old.
1417 Unexpected Answer Communication error. Try again.
1418 Failed To Receive
Command
Check communications cable.
Error No. Error Text Action