Basic Management Tasks
4-2
4
Web – Click System, System Information. Specify the system name, location, and
contact information for the system administrator, then click Apply. (This page also
includes a Telnet button that allows access to the Command Line Interface via Telnet.)
Figure 4-1 System Information
CLI – Specify the hostname, location and contact information.
Console(config)#hostname R&D 5 19-1
Console(config)#snmp-server location WC 9 20-4
Console(config)#snmp-server contact Ted 20-4
Console(config)#exit
Console#show system 19-6
System Description: 24 port Ethernet Metro Access Switch
*
System OID String: 1.3.6.1.4.1.259.8.2.2
System Information
System Up Time: 0 days, 0 hours, 24 minutes, and 7.84 seconds
System Name: R&D 5
System Location: WC 9
System Contact: Ted
MAC Address (Unit1): 00-12-CF-21-DC-E0
Web Server: Enabled
Web Server Port: 80
Web Secure Server: Enabled
Web Secure Server Port: 443
Telnet Server: Enable
Telnet Server Port: 23
Jumbo Frame: Disabled
Power Module A Status : UP
Power Module B Status : Not present
Power Module A Type :
Power Module B Type : [None]
Fan(1) : OK
Fan(2) : OK
Fan(3) : OK